{"id":633,"date":"2019-07-15T14:36:37","date_gmt":"2019-07-15T14:36:37","guid":{"rendered":"https:\/\/beta.research.ece.ncsu.edu\/bhattacharya\/?page_id=633"},"modified":"2019-08-09T15:47:24","modified_gmt":"2019-08-09T15:47:24","slug":"asynchronous-microgrid-power-conditioning-system","status":"publish","type":"page","link":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/","title":{"rendered":"Asynchronous Microgrid Power Conditioning System"},"content":{"rendered":"\n<h3 class=\"wp-block-heading\">Sanket Parashar<\/h3>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<p style=\"font-size:22px\"><em>Funding Source:<\/em> Power America<\/p>\n\n\n\n<p style=\"font-size:22px\"><em>Objective: <\/em> To delvelop Microgrid Power Conditioning System with Series Connected 10kV SiC MOSFETs <\/p>\n\n\n\n<p style=\"font-size:22px\"><em>Summary: <\/em> The project addresses a Medium-Voltage Asynchronous Micro-grid Power  Conditioning system  enabled by HV SiC devices to Asynchronously flow  power from microgrids to the larger grid. The Asynchronous Microgrid  Power Conditioning System is a modular MVAC (13.8kV AC) to MVAC (4,160 V  AC and 13.8 kV AC) power conditioning systems blocks (PCSB) that can be  used for grid interconnection of Megawatt-scale flow control microgrids  (Asynchronous MVAC Microgrids), bi-directional power flow capablity and  scalablity so that they can be used for a broad range of flow control  microgrids of different scale (100 kW to multi MW) including microgrids  which have net generation or net load flow at point of connection of  larger grids. This modular approach is intended to result in  higher-volume, lower-cost power electronics building blocks that service  many applications at standard voltages: 4,160 V AC and 13.8 kV AC. This  Microgrid PCS solution should enable multi-port integration of  renewable energy sources to the main grid. The Microgrid PCS solution  can be implemented with 3.3 kV to 10 kV SiC MOSFET modules. The modular  converters will utilize high-voltage, high frequency (10 kHz) power  electronics to reduce cost, size , footprint, volume and weight and to  provide the bandwidth (voltage control BW = 300 Hz and current control  BW = 1 kHz) needed for both the grid-facing and microgrid facing  functions required by interconnection standards plus functions required  for a wide range of generator, storage and load applications. <\/p>\n\n\n\n<p style=\"font-size:22px\"><em>Impact: <\/em> The research will revolutionize integration of renewables with the grid. <\/p>\n\n\n\n<div style=\"height:20px\" aria-hidden=\"true\" class=\"wp-block-spacer\"><\/div>\n\n\n\n<div class=\"wp-block-image\"><figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/research.ece.ncsu.edu\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-1024x768.jpg\" alt=\"\" class=\"wp-image-636\" width=\"727\" height=\"545\" srcset=\"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-1024x768.jpg 1024w, https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-300x225.jpg 300w, https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-768x576.jpg 768w\" sizes=\"auto, (max-width: 727px) 100vw, 727px\" \/><\/figure><\/div>\n","protected":false},"excerpt":{"rendered":"<p>Sanket Parashar Funding Source: Power America Objective: To delvelop Microgrid Power Conditioning System with Series Connected 10kV SiC MOSFETs Summary: The project addresses a Medium-Voltage&#8230;<\/p>\n","protected":false},"author":54,"featured_media":0,"parent":27,"menu_order":0,"comment_status":"closed","ping_status":"closed","template":"page-fullwidth.php","meta":{"_acf_changed":false,"_uag_custom_page_level_css":"","footnotes":""},"class_list":["post-633","page","type-page","status-publish","hentry"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Asynchronous Microgrid Power Conditioning System - Power Electronics Research Group<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Asynchronous Microgrid Power Conditioning System - Power Electronics Research Group\" \/>\n<meta property=\"og:description\" content=\"Sanket Parashar Funding Source: Power America Objective: To delvelop Microgrid Power Conditioning System with Series Connected 10kV SiC MOSFETs Summary: The project addresses a Medium-Voltage...\" \/>\n<meta property=\"og:url\" content=\"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/\" \/>\n<meta property=\"og:site_name\" content=\"Power Electronics Research Group\" \/>\n<meta property=\"article:modified_time\" content=\"2019-08-09T15:47:24+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/research.ece.ncsu.edu\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-1024x768.jpg\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/\",\"url\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/\",\"name\":\"Asynchronous Microgrid Power Conditioning System - Power Electronics Research Group\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/wp-content\\\/uploads\\\/sites\\\/10\\\/2019\\\/07\\\/IMG_3620-Sanket-Parashar-1-1024x768.jpg\",\"datePublished\":\"2019-07-15T14:36:37+00:00\",\"dateModified\":\"2019-08-09T15:47:24+00:00\",\"breadcrumb\":{\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/#primaryimage\",\"url\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/wp-content\\\/uploads\\\/sites\\\/10\\\/2019\\\/07\\\/IMG_3620-Sanket-Parashar-1-1024x768.jpg\",\"contentUrl\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/wp-content\\\/uploads\\\/sites\\\/10\\\/2019\\\/07\\\/IMG_3620-Sanket-Parashar-1-1024x768.jpg\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/asynchronous-microgrid-power-conditioning-system\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Research\",\"item\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/research-projects\\\/\"},{\"@type\":\"ListItem\",\"position\":3,\"name\":\"Asynchronous Microgrid Power Conditioning System\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/#website\",\"url\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/\",\"name\":\"Power Electronics Research Group\",\"description\":\"NC State ECE\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/research.ece.ncsu.edu\\\/bhattacharya\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Asynchronous Microgrid Power Conditioning System - Power Electronics Research Group","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/","og_locale":"en_US","og_type":"article","og_title":"Asynchronous Microgrid Power Conditioning System - Power Electronics Research Group","og_description":"Sanket Parashar Funding Source: Power America Objective: To delvelop Microgrid Power Conditioning System with Series Connected 10kV SiC MOSFETs Summary: The project addresses a Medium-Voltage...","og_url":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/","og_site_name":"Power Electronics Research Group","article_modified_time":"2019-08-09T15:47:24+00:00","og_image":[{"url":"https:\/\/research.ece.ncsu.edu\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-1024x768.jpg","type":"","width":"","height":""}],"twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/","url":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/","name":"Asynchronous Microgrid Power Conditioning System - Power Electronics Research Group","isPartOf":{"@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/#website"},"primaryImageOfPage":{"@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/#primaryimage"},"image":{"@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/#primaryimage"},"thumbnailUrl":"https:\/\/research.ece.ncsu.edu\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-1024x768.jpg","datePublished":"2019-07-15T14:36:37+00:00","dateModified":"2019-08-09T15:47:24+00:00","breadcrumb":{"@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/#primaryimage","url":"https:\/\/research.ece.ncsu.edu\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-1024x768.jpg","contentUrl":"https:\/\/research.ece.ncsu.edu\/wp-content\/uploads\/sites\/10\/2019\/07\/IMG_3620-Sanket-Parashar-1-1024x768.jpg"},{"@type":"BreadcrumbList","@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/asynchronous-microgrid-power-conditioning-system\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/"},{"@type":"ListItem","position":2,"name":"Research","item":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/research-projects\/"},{"@type":"ListItem","position":3,"name":"Asynchronous Microgrid Power Conditioning System"}]},{"@type":"WebSite","@id":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/#website","url":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/","name":"Power Electronics Research Group","description":"NC State ECE","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"}]}},"uagb_featured_image_src":{"full":false,"thumbnail":false,"medium":false,"medium_large":false,"large":false,"1536x1536":false,"2048x2048":false,"blog_thumb":false,"medium-featured":false,"large-featured":false,"sidebar-featured":false,"boxed-full-featured":false,"fullwidth-featured":false,"directory-thumb":false},"uagb_author_info":{"display_name":"bilica","author_link":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/author\/bilica\/"},"uagb_comment_info":0,"uagb_excerpt":"Sanket Parashar Funding Source: Power America Objective: To delvelop Microgrid Power Conditioning System with Series Connected 10kV SiC MOSFETs Summary: The project addresses a Medium-Voltage...","_links":{"self":[{"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/pages\/633","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/pages"}],"about":[{"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/types\/page"}],"author":[{"embeddable":true,"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/users\/54"}],"replies":[{"embeddable":true,"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/comments?post=633"}],"version-history":[{"count":1,"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/pages\/633\/revisions"}],"predecessor-version":[{"id":637,"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/pages\/633\/revisions\/637"}],"up":[{"embeddable":true,"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/pages\/27"}],"wp:attachment":[{"href":"https:\/\/research.ece.ncsu.edu\/bhattacharya\/wp-json\/wp\/v2\/media?parent=633"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}